AXEON BT – Series Reverse Osmosis Systems further expand the AXEON commercial reverse osmosis lineup with two models designed for 1,500 and 2,000 gallons per day. Featuring 4.5″ diameter sediment and carbon block pre-filters, low energy memnranes and a high pressure pump, the BT–Series sets the industry standard for highperformance reverse osmosis systems. These models can also be upgraded with options for higher recovery rates by adding the concentrate recycle option.
FEATURES
- Manual On and Off Control Switch
- AXEON HF1–Series Low Energy Membrane Elements
- AXEON 5-Micron Sediment Pre-Filter
- AXEON 10-Micron Carbon Block Pre-Filter
- SS –Series Membrane Housings
- Pentek® Single O-Ring Filter Housings
- Fluid-O-Tech™ Low Lead Brass Rotary Vane High Pressure Pump
- 316L Stainless Steel Concentrate Valve
- Composite Feed Solenoid Valve
- Feed Low Pressure Switch 15-30 psi
- Permeate and Concentrate Flow Meter
- Pre-Filter Pressure Gauges 0-100 psi
- Pump Pressure Gauge 0-300 psi
- ODP High Efficiency Carbonator Motor
- John Guest® Push/Pull Fittings with Locking Safety Clips
- White Powder Coated Aluminum Frame
BENEFITS
- Fully Equipped and Customizable
- Lightweight Design
- Compact Space Saving Design
- Components Easily Accessible
- Pre-Plumbed, Wired and Assembled
- Factory Tested and Preserved
- Low Operation and Maintenance Costs
- Easy Maintenance and Servicing
- 1-Year Limited Warranty
SPECIFICATIONS
| MODELS | BT–1500 | BT–2000 | |
|---|---|---|---|
| Design | |||
| Configuration | Single Pass | Single Pass | |
| Feedwater Source (ppm)A | TDS < 2000 | TDS < 2000 | |
| Standard Recovery Rate % | 41 | 63 | |
| Recovery with Concentrate Recycle % | Up to 75 | Up to 75 | |
| Flow RatesB | |||
| Permeate Flow (gpm / lpm) | 1.04 / 3.93 | 1.38 / 5.22 | |
| Minimum Feed Flow (gpm / lpm) | 2.04 / 7.7 | 2.35 / 8.89 | |
| Minimum Concentrate Flow (gpm / lpm) | 1 / 3.78 | 1 / 3.78 | |
| Connections | |||
| Feed (in) | 1 FNPT | 1 FNPT | |
| Permeate (in) | 3/8 QC | 3/8 QC | |
| Concentrate (in) | 3/8 QC | 3/8 QC | |
| Membranes | |||
| Membrane Per Vessel | 1 | 1 | |
| Membrane Quantity | 2 | 3 | |
| Membrane Size | 2540 | 2540 | |
| Nominal Salt Rejection % | 99 | 99 | |
| Vessels | |||
| Vessel Array | 1:1 | 1:1:1 | |
| Vessel Quantity | 2 | 3 | |
| Pumps | |||
| Pump Type | Rotary Vane 601 Brass | Rotary Vane 1001 Brass | |
| Motor HP | 3/4 | 3/4 | |
| RPM @ 60Hz (50 Hz) | 1725 (1465) | 1725 (1465) | |
| System Electrical | |||
| Standard Voltage + Amp DrawC | 110V, 60Hz, 1PH, 11.0A | 110V, 60Hz, 1PH, 11.0A | |
| High Voltage Service + Amp DrawC | 220V, 60Hz, 1PH, 5.6A 220V, 50Hz, 1PH, 6.6A |
220V, 60Hz, 1PH, 5.6A 220V, 50Hz, 1PH, 6.6A |
|
| System Dimensions | |||
| Approximate Dimensions D L x W x H (in /cm) |
19 x 23 x 46 / 48 x 58 x 116 | 19 x 23 x 46 / 48 x 58 x 116 | |
| Approximate Weight (lbs / kg) | 105 / 47.63 | 115 / 52.16 | |
Test Parameters: 550 TDS Filtered (5-Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / 10.34 bar Operating Pressure, 77°F / 25°C, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.
Note: All 50Hz systems come standard with AXEON HF4 –Series Extra Low Energy Membrane Elements.
A. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.
B. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.
C. Varies with motor manufacturer.
D. Does not include operating space requirements.
OPERATING LIMITS E
| Maximum Feed Temperature (°F / °C) | 85 / 29 | Maximum Turbidity (NTU) | 1 |
| Minimum Feed Temperature (°F / °C) | 40 / 4 | Maximum Free Chlorine (ppm) | 0 |
| Maximum Ambient Temperature (°F / °C) | 120 / 49 | Maximum TDS (ppm) | 2,000 |
| Minimum Ambient Temperature (°F / °C) | 40 / 4 | Maximum Hardness (gpg) | 0 |
| Maximum Feed Pressure (psi / bar) | 85 / 6 | Maximum pH (continuous) | 11 |
| Minimum Feed Pressure (psi / bar) | 45 / 3 | Minimum pH (continuous) | 2 |
| Maximum Operating Pressure (psi / bar) | 150 / 10 | Maximum pH (cleaning 30 minutes) | 13 |
| Maximum Feed Silt Density Index (SDI) | < 3 | Minimum pH (cleaning 30 minutes) | 1 |
E. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.
OPTIONS
- Minitrol Computer Controller
- Minitrol IF Computer Controller with Feed Flush
- S –150 Computer Controller with Feed Flush
- AXEON HF4 –Series Extra Low Energy Membrane Elements
- AXEON HF5 –Series Ultra Low Energy Membrane Elements
- AXEON NF3 – Series Nanofiltration Membrane Elements
- AXEON NF4 – Series Nanofiltration Membrane Elements
- FRP–Series Membrane Housings
- Fluid-O-Tech™ Stainless Steel Rotary Vane Pump
- Blending Valve
- Chemical Pump Outlet
- Concentrate Recycle Valve with Flow Meter
- High Pressure Tank Switch
- HM Digital™ PSC–150 TDS/Conductivity Controller
- Permeate Flush with Pressure Tank
- Permeate Flush with Atmospheric Tank
- Permeate Flush with Mechanical Float
- Permeate Sample Ports
- Wooden Shipping Crate
THE RIGHT SOLUTION FOR YOU
Contact us today for more information about our products and services.
CONTACT US