T3 – Series Reverse Osmosis Systems

AXEON T3 – Series Reverse Osmosis Systems are designed and manufactured for seawater applications requiring capacities of 3,000 to 7,000 gallons per day. AXEON T3 – Series Reverse Osmosis Systems are equipped with premium components, which include a 316L plunger–type pump for high performance and corrosion resistance, a high grade corrosion resistant aluminum frame, a programmable computer controller with many built–in features and fiberglass membrane housings for durability.

Contact us today for availability or a quote
CONTACT US
  • S – 150 Computer Controller
    • LCD Backlit Display
    • Pre–Treatment Lockout
    • Tank Level Input
    • Low and High Pressure Monitoring and Alarm
    • Permeate TDS Monitoring
    • Hour Meter
    • Feed Flush
  • High Rejection Sea Water Membranes
  • AXEON FRP – Series Membrane Housings
  • AXEON 5 – Micron Sediment Pre–Filter
  • AXEON by Pentek® Single O–Ring Cartridge Housing
  • Permeate and Concentrate Flow Meters
  • GF Motorized Valve PVC
  • 0 – 100 psi Pre–Filter Out Pressure Gauge
  • 0 – 1500 psi Concentrate Pressure Gauge
  • AXEON 316L Stainless Steel Needle Valve
  • SS Feed Low Pressure Switch
  • SS Pump High Pressure Switch
  • Pressure Relief Valve
  • Pressure Regulator
  • CAT® 316L High Pressure Pump
  • TEFC Motor with Thermal Motor Protection
  • White Powder Coated Aluminum Frame
  • High Pressure 316L Stainless Steel Tubing and Fittings
  • High Pressure Hose with Reusable SS Fittings
  • Configuration

    Single Pass
  • Feedwater Source†

    <45,000 ppm
  • System Recovery with Recycle %

    27 – 48
  • Nominal Salt Rejection %

    99.4
  • Permeate Flow Rate (gpm / lpm)

    2.70 / 10.22
  • Concentrate Flow Rate (minimum) (gpm / lpm)

    4.00 / 15.00
  • Feed Connection (in)

    1 FNPT
  • Permeate Connection (in)

    1 FNPT
  • Concentrate Connection (in)

    1 FNPT
  • Membrane(s) Per Vessel

    1
  • Membrane Quantity

    4
  • Membrane Size

    4040
  • Vessel Array

    1:1:1:1
  • Vessel Quantity

    4
  • Pump Type

    Piston
  • Motor HP

    7.5
  • RPM at 60Hz

    3600
  • Controller

    S – 150
  • High Voltage Service + Amp Draw

    220V, 3PH, 60Hz, 20A**
  • Approximate Dimensions* L x W x H (in / cm)

    60 x 26 x 48.5 / 152.4 x 66.0 x 123.2
  • Approximate Weight (lbs / kg)

    270 / 122.47
  • Configuration

    Single Pass
  • Feedwater Source†

    <45,000 ppm
  • System Recovery with Recycle %

    27 – 48
  • Nominal Salt Rejection %

    99.4
  • Permeate Flow Rate (gpm / lpm)

    3.47 / 13.13
  • Concentrate Flow Rate (minimum) (gpm / lpm)

    4.00 / 15.00
  • Feed Connection (in)

    1 FNPT
  • Permeate Connection (in)

    1 FNPT
  • Concentrate Connection (in)

    1 FNPT
  • Membrane(s) Per Vessel

    1
  • Membrane Quantity

    5
  • Membrane Size

    4040
  • Vessel Array

    1:1:1:1:1
  • Vessel Quantity

    5
  • Pump Type

    Piston
  • Motor HP

    7.5
  • RPM at 60Hz

    3600
  • Controller

    S – 150
  • High Voltage Service + Amp Draw

    220V, 3PH, 60Hz, 20A**
  • Approximate Dimensions* L x W x H (in / cm)

    60 x 26 x 48.5 / 152.4 x 66.0 x 123.2
  • Approximate Weight (lbs / kg)

    300 / 136.08
  • Configuration

    Single Pass
  • Feedwater Source†

    <45,000 ppm
  • System Recovery with Recycle %

    27 – 48
  • Nominal Salt Rejection %

    99.4
  • Permeate Flow Rate (gpm / lpm)

    4.80 / 18.17
  • Concentrate Flow Rate (minimum) (gpm / lpm)

    4.00 / 15.00
  • Feed Connection (in)

    1 FNPT
  • Permeate Connection (in)

    1 FNPT
  • Concentrate Connection (in)

    1 FNPT
  • Membrane(s) Per Vessel

    1
  • Membrane Quantity

    6
  • Membrane Size

    4040
  • Vessel Array

    1:1:1:1:1:1
  • Vessel Quantity

    6
  • Pump Type

    Piston
  • Motor HP

    7.5
  • RPM at 60Hz

    3600
  • Controller

    S – 150
  • High Voltage Service + Amp Draw

    220V, 3PH, 60Hz, 20A**
  • Approximate Dimensions* L x W x H (in / cm)

    60 x 26 x 48.5 / 152.4 x 66.0 x 123.2
  • Approximate Weight (lbs / kg)

    330 / 149.68
  • Design Temperature (°F / °C)

    77 / 25

    Maximum Turbidity (NTU)

    1
  • Maximum Feed Temperature (°F / °C)

    85 / 29

    Maximum Free Chlorine (ppm)

    0
  • Minimum Feed Temperature (°F / °C)

    40 / 4

    Maximum TDS (ppm)

    < 45,000
  • Maximum Ambient Temperature (°F / °C)

    120 / 49

    Maximum Hardness (gpg)

    1
  • Minimum Ambient Temperature (°F / °C)

    40 / 4

    Maximum pH (Continuous)

    11
  • Maximum Feed Pressure (psi / bar)

    65 / 4

    Minimum pH (Continuous)

    2
  • Minimum Feed Pressure (psi / bar)

    45 / 3

    Maximum pH (Cleaning 30 Minutes)

    13
  • Maximum Operating Pressure (psi / bar)

    1,000 / 69

    Minimum pH (Cleaning 30 Minutes)

    1
  • Maximum Feed Silt Density Index (SDI)

    <3

Test Parameters: 35,000 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 950 psi / 65.5 bar Operating Pressure, 77°F / 25°C, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.

** Varies with motor manufacturer.

† Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.

†† System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.

††† Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.