LC – Series Reverse Osmosis Systems

AXEON LC – Series Reverse Osmosis Systems are manufactured for light commercial applications and feature a compact space–saving design. The versatile design allows for either wall–mounted or freestanding operation. The LC – Series Systems come preassembled and ready for immediate online service with minimal set up and simple utility connections. AXEON LC – Series Reverse Osmosis Systems have been engineered for capacities ranging from 750 to 1,500 gallons per day and feature a Fluid–O–TechTM Low Lead Brass Rotary Vane Pump designed for enhanced performance.

Contact us today for availability or a quote
CONTACT US
  • White Powder Coated Steel Bracket
  • AXEON 2.5” x 20” 5 – Micron Sediment Pre–Filter
  • AXEON 2.5” x 20” 10 – Micron Carbon Block Pre–Filter (on LC – 750)
  • AXEON by Pentek® 20” Slim Line Cartridge Housings
  • Fluid–O–TechTM Low Lead Brass Rotary Vane High Pressure Pump
  • ODP High Efficiency Carbonator Motor
  • AXEON HF5 – Series Ultra Low Energy Membrane Elements
  • Permeate Flow Meter
  • Concentrate Flow Meter with SS Integrated Needle Valve
  • Concentrate Recycle Flow Meter with SS Integrated Needle Valve
  • Feed Solenoid Valve
  • 0 – 300 psi Pump Pressure Gauge
  • 0 – 100 psi Post–Filter Pressure Gauge
  • 0 – 100 psi Permeate Pressure Gauge
  • John Guest® Push/Pull Fittings with Locking Safety Clips
  • Low Pressure Switch for Pump Protection
  • Permeate High Pressure Switch
  • HM Digital® DM – 2 Dual TDS Meter
  • 20” Floor Stand
  • Fluid–O–TechTM Stainless Steel Rotary Vane Pump
  • Blending Valve
RO SYSTEM CAPACITY MEMBRANE ELEMENTS LINE INCHES (NPT, IN) SYSTEM DIMENSIONS
L X D X H (IN / CM)
APPROX. SHIPPING
WEIGHT (LB / KG)
MODEL GPD LPD STANDARD
RECOVERY
RATE
QTY SIZE (IN)
(DIA. X L)
INLET PRODUCT WASTE
LC – 750
750 2,839 Up to 75% 1 3.0 x 18 0.50 0.38 0.38 17 x 13 x 34 /
43 x 33 x 86
50 / 23
LC – 1500
1,500 5,678 Up to 75% 2 3.0 x 18 0.50 0.38 0.38 17 x 13 x 34 /
43 x 33 x 86
60 / 27

* Post filter not available on the LC – 1500 model.

Maximum Feed Temperature (°F / °C)
85 / 29
Maximum Turbidity (NTU)
1
Minimum Feed Temperature (°F / °C)
40 / 4
Maximum Free Chlorine (ppm)
0
Maximum Ambient Temperature (°F / °C)
120 / 49
Maximum TDS (ppm)
Up to 1,000
Minimum Ambient Temperature (°F / °C)
40 / 4
Maximum Hardness (gpg)
1
Maximum Feed Pressure (psi / bar)
70 / 4
Maximum pH (Continuous)
11
Minimum Feed Pressure (psi / bar)
40 / 3
Minimum pH (Continuous)
2
Maximum Operating Pressure (psi / bar)
90 / 6
Maximum pH (Cleaning 30 Minutes)
13
Maximum Feed Silt Density Index (SDI)
<3
Minimum pH (Cleaning 30 Minutes)
1

Test Parameters: 550 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 70 psi / 4.83 bar Operating Pressure, 77°F / 25°C, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.

** Varies with motor manufacturer.

† Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.

†† System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.

††† Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.