Technical Articles

Membrane filtration underpins every stage of modern semiconductor device fabrication by delivering the ultra-high-purity water and process chemicals essential for defect-free wafers. Sub-micron particles can abrade photoresist layers, dissolved gases such as oxygen or chlorine can corrode fine metallization, and trace organic compounds can interfere with chemical-mechanical planarization. By systematically stripping out these contaminants before rinsing, etching, and slurry delivery, membrane systems safeguard yield and reliability in an industry where atomic-scale precision is the standard.
Membrane Filtration Technologies Overview
Reverse Osmosis (RO)
Single-pass reverse osmosis systems, like AXEON’s R1-Series, use high-rejection thin-film composite membranes to remove ≥99% of dissolved solids in one stage, producing ultrapure water for CMP slurry, wafer rinsing, and photolithography. Double-pass RO, exemplified by the RDP-Series, channels RO concentrate through a second membrane train to achieve near-zero waste and ultra-low total dissolved solids levels for the strictest UPW demands
Nanofiltration & Ultrafiltration
Nanofiltration and ultrafiltration employ semi-permeable membranes with pore sizes ranging from 0.001–0.1 µm to selectively strip organics, colloids, and sub-micron particles while allowing monovalent ions to pass. AXEON’s NF3- and NF4-Series NF elements integrate seamlessly with RO trains to protect downstream membranes and extend system life[10].
Depth & Cartridge Filtration
Depth and cartridge filters provide critical pre- and post-RO protection. A 5 µm sediment cartridge removes bulk particulates to prevent membrane fouling, while activated carbon cartridges adsorb chlorine, organic compounds, and residual disinfectants, safeguarding membrane integrity and water taste[1].
Gas & Air Filtration
High-efficiency particulate air (HEPA) and ultra-low particulate air (ULPA) filters ensure cleanroom air meets semiconductor standards by capturing ≥99.97% of ≥0.3 µm particulates. Gas-phase carbon filters remove volatile organic compounds and chemical impurities from process gases, preserving device performance and yield.
Key Applications in Microelectronics
Ultra-Pure Water (UPW) Systems
Ultra-pure water (UPW) is the bedrock of semiconductor device fabrication, supplying particle-free, ion-free rinse water for critical steps like chemical-mechanical planarization (CMP) slurry preparation, wafer cleaning, and photolithography support. UPW systems strip feedwater down to <1 ppb total dissolved solids and <1 particle/100 mL (≥0.05 µm) using a staged train-pre-filtration, R1-Series reverse osmosis, mixed-bed deionization, and final polishing-to prevent defects in photoresist patterns and metal interconnects. Consistent UPW quality ensures dimensional control at the nanometer scale and maximizes yield by eliminating sub-micron particulates and trace ionic contaminants that can induce corrosion or dielectric failures.
CMP Slurry & Chemical Feed
In CMP, ultraclean slurry is circulated across wafer surfaces under controlled pressure to planarize film layers. Membrane filtration units-often integrated into R1-Series skids-remove worn abrasive particles and spent chemistry via crossflow ultrafiltration or nanofiltration elements. Periodic clean-in-place (CIP) sequences and back-flush recirculation loops restore membrane permeability and extend service life. This continuous particle removal preserves uniform slurry size distribution, prevents membrane fouling, and stabilizes pressure drop, thereby maintaining planarization rates and minimizing wafer defects.
Gas Purification & Dissolved Gas Control
High-purity process gases and ultrapure water demand removal of volatile organic compounds (VOCs), chloramines, and dissolved gases that can oxidize or pucker photoresist and metal layers. Gas-phase carbon filters (catalytic or activated) eliminate VOCs and trace organics, while membrane degassers strip oxygen and chlorine from UPW. Controlled dissolved-gas levels avert micro-bubbles during spin coating or CMP, ensuring film uniformity, adhesion integrity, and defect-free surfaces. Continuous monitoring and replacement of gas-phase cartridges safeguard cleanroom atmosphere and chemical feed quality.
AXEON Water Solutions for Microelectronics
R1-Series Reverse Osmosis Systems
The skid-mounted R1-Series delivers 1,800–21,600 gallons per day of ultrapure water within a compact footprint. Its ultra-low energy HF5 membranes, stainless steel booster pump, and programmable S-150 controller ensure maximum recovery and minimal maintenance.
X1-Series Reverse Osmosis Systems
Engineered for industrial tap water, the X1-Series produces 22–120 gallons per minute of high-purity water using ultra-low energy membranes with 10 percent greater membrane area. Each pre-plumbed, pre-wired skid features digital flow sensors and a user-friendly controller for straightforward operation.
M1 & M2 Brackish Water RO Systems
The M1 and M2-Series treat brackish feedwaters, yielding 12,000–36,000 gallons per day at recoveries up to 75 percent. Integrated concentrate recycle loops reclaim waste brine for near zero-waste operation, while multi-stage pumps and FRP housings deliver robust, low-maintenance performance.
N-Series Commercial RO Systems
N-Series commercial units produce 2,000–16,000 gallons per day of >98 percent TDS-reduced water. Each skid incorporates an RO controller with digital TDS monitoring, pre-filtration cartridges, pressure gauges, and automatic feed flush, simplifying system monitoring and service.
Packaged & Mobile Systems
AXEON’s PWS pack skids, CIP clean-in-place modules, and repressurization skids arrive fully assembled, pre-wired, and pre-plumbed for plug-and-play installation. Turnkey containerized units integrate pretreatment, RO trains, and storage in a transportable enclosure for rapid deployment.
Media Filtration (AC, CC, ZE-Series)
AC, CC, and ZE media filters stage 5 micron sediment removal, activated carbon for organic and chlorine adsorption, catalytic carbon for chloramine destruction, and zeolite for turbidity control-ensuring downstream RO membranes and processes receive contaminant-free feedwater.
Designing Your Filtration Train
Designing a filtration train for microelectronics manufacturing begins by matching the feedwater’s SDI, TDS, chlorine and turbidity profile to the appropriate pre-treatment modules-5 µm sediment cartridges, activated or catalytic carbon (AC/CC) and zeolite (ZE) filters- ensuring effective filtration and protecting downstream membranes. Next, reverse osmosis systems (R1-Series up to 21,600 gpd; X1/X2/X3 for tap, brackish or seawater) remove over 98 percent of dissolved solids. A final polishing stage (ultrafiltration, mixed-bed DI or EDI) delivers ultra-pure water for rinsing and photolithography. Automated S-Series controllers integrate clean-in-place cycles and real-time diagnostics, while modular skids and packaged/mobile units optimize footprint, simplify installation, and ensure consistent purity, uptime, and yield.
Conclusion
Tailored membrane filtration systems ensure the purity and consistency required for semiconductor device fabrication, boosting product quality, maximizing yield, and reducing defect-induced downtime. By integrating advanced membrane technology-from pre-filtration to polishing-AXEON’s solutions maintain ultra-pure water, control dissolved gases, and eliminate particulates throughout the manufacturing process. With comprehensive design, deployment, and service support, AXEON Water Technologies partners on contamination control, system automation, and maintenance, delivering reliable, high-efficiency filtration trains that safeguard microelectronics manufacturing integrity and drive sustainable production success.
THE RIGHT SOLUTION FOR YOU
Contact us today for more information about our products and services.
CONTACT US