Concentrate Recycle

Concentrate Recycle

The main purpose of a concentrate recycle loop in a reverse osmosis system is to reduce the amount of concentrate or waste water flowing to the drain. Recycle loops are also used to maintain an optimum flow velocity across the membrane surface and reduce individual membrane recovery.

A recycle loop takes a portion of the concentrate flow which would have otherwise gone to drain and returns it to the feed of the RO pump in a continuous loop. Reducing the concentrate flow to drain achieves a higher system “recovery” percentage. Pump sizing needs to take the additional flow coming from the concentrate recycle loop into consideration.

Careful attention must be paid to the feed water analysis. Concentrating the waste stream to a higher degree can only be done to a certain point before fouling will occur in the membranes. This fouling point will vary with each feed water.

The examples shown below are for the same system operating at 70% recovery, the first example with recycle and the second without:
 

System Design Overview with Recycle Loop


System Design Overview with Recycle Loop
 
Stream # Flow (gpm) Pressure (psig) TDS (mg/l)
1 = Feed 6.00 0.00 914.82
3 = Pump Flow 9.00 218.37 165.21
4 = Recycle Flow 3.00 179.92 3087.03
5 = Concentrate Flow 4.80 179.92 3087.03
6 = Final Drain Flow 1.80 179.92 3087.03
7 = Permeate Flow 4.20 -- 5.98
7 = Permeate / 1 = Feed % Recovery 70.00 70.00
*Design Warnings: None

 

System Design Overview without Recycle Loop



 
Stream # Flow (gpm) Pressure (psig) TDS (mg/l)
1 = Feed 6.00 0.00 914.82
3 = Pump Flow 6.00 210.50 930.59
5 = Concetrate / Drain Flow 1.80 179.92 3088.81
7 = Permeate Flow 4.20 -- 4.83
7 = Permeate Flow / 1 =Feed % Recovery 70.00 70.00
*Design Warnings:
   CAUTION: The concentrate flow rate is less than the recommended minimum flow. Please change your system design to increase concentrate flow rates.
   WARNING: Maximum element recovery has been exceeded. Please change your system design to reduce the element recoveries. (Product: TW30-4040, Limit: 25.00%)


Example 1: Without recycle the concentrate to drain would have been 4.8 GPM. A flow of 3 GPM is being returned to the feed in a recycle loop. This reduced the drain flow to 1.8 GPM and made the overall system recovery of 70% possible.

Example 2: 70% recovery without recycle in this system design is too high. System design warnings are shown.

Without a recycle loop the system recovery would need to be reduced to approximately 50% in order to maintain the required minimum concentrate flow and not exceed recommend per element recovery.