Home Products Membrane Membrane Elements AXEON HF5-Series Ultra Low Energy Membrane Elements

AXEON HF5-Series Ultra Low Energy Membrane Elements

Made in the USAAXEON Ultra Low Energy HF5-Series Reverse Osmosis Membranes are manufactured using the industry’s leading membrane film technology. These membranes offer reliability, high performance and deliver consistent results. They provide increased production, high rejection rates and ultra low energy consumption by operating at low applied pressures.

AXEON HF5-Series Membranes are the only elements on the market that operates at a pressure of only 80 psi – which equals more energy savings. AXEON HF5-Series Membranes are available in all standard 4-inch commercial sizes and feature a protective tape wound exterior. AXEON HF5-Series Membranes are the best choice to counter the negative effects of cold temperatures on reverse osmosis production. All elements are shipped dry for an indefinite shelf life and easier handling. AXEON HF5-Series Membrane Elements are 100% vacuum integrity tested and may also be ordered as individually wet tested.

  • Ultra Low Energy
  • Improved System Performance
  • Superior Quality
  • Individually Vacuum Tested
  • 1-Year Limited Warranty
  • Made in the U.S.A.
Part Number 208125 208083 208084 200392 200393 200394
Model HF5-2514 HF5-2521 HF5-2540 HF5-4014 HF5-4021 HF5-4040
Permeate Flow Rate (gpd / lpd)
@ 80psi (5.51bar)
225 / 850 400 / 1512 850 / 3213/td> 600 / 2268 1000 / 3780 2500 / 9450
Permeate Flow Rate (gpd / lpd)
@ 100psi (6.89bar)
300 / 1134 460 / 1738 1000 / 3780 720 / 2722 1200 / 4536 3000 / 11340
Stabilized Salt Rejection 98.5% 98.5% 98.5% 98.5% 98.5% 98.5%
# / Case 1 1 1 1 1 1
Operating Limits  
Max. Operating Temperature (°F / °C) 113 / 45 113 / 45 113 / 45 113 / 45 113 / 45 113 / 45
Max. Operating Pressure (psi / bar) 400 / 27.58 400 / 27.58 400 / 27.58 400 / 27.58 400 / 27.58 400 / 27.58
Max. Feed Flow Rate (gpm / lpm) 14 / 52.9 14 / 52.9 14 / 52.9 14 / 52.9 14 / 52.9 14 / 52.9
pH Range - Continuous* 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11
pH Range - Short Term Cleaning (30 Min) 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13
Max. SDI 5 5 5 5 5 5
Max. Turbidity < 1 < 1 < 1 < 1 < 1 < 1
Chlorine Tolerance (ppm) 0 0 0 0 0 0
Materials of Construction  
Membrane Type Thin Film Composite
Material Polyamide
Configuration Spiral Wound
Dimensions (in / cm)  
A 14 / 35.56 21 / 53.34 40 / 101.60 14 / 35.56 21 / 53.34 40 / 101.60
B 1.1 / 2.79 1.1 / 2.79 1.1 / 2.79 1.1 / 2.79 1.1 / 2.79 1.1 / 2.79
C 0.75 / 1.91 0.75 / 1.91 0.75 / 1.91 0.75 / 1.91 0.75 / 1.91 0.75 / 1.91
D 2.40 / 60.96 2.40 / 60.96 2.40 / 60.96 3.95 / 10.03 3.95 / 10.03 3.95 / 10.03

Test Parameters: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water, 77 Degrees F, 15% Permeate Recovery, 6.5 - 7.0 pH Range, at the Specified Operating Pressure. Data Taken After 30 Minutes of Operation. Maximum Pressure drop for each element is 10 psi. Minimum salt rejection is 96%. Permeate flow for individual elements may vary +/- 20%.

 

* Maximum temperature for continuous operations above pH10 is 95° F (35°C)

 

Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, the manufacturer recommends removing residual free chlorine by pretreatment prior to membrane exposure. Wet tested membrane elements must be kept sealed and moist when in storage. Drying out may occur and damage the membrane permanently. Prevent elements from freezing or being exposed to direct sunlight. Wet tested elements are vacuum sealed in a polyethylene bag containing AXEON M-100 Membrane Preservative and then packaged in a cardboard box. Discard the permeate for the first twenty-four hours of operation. The permeate flow (product water flow) varies with feed water temperature. For membrane warranty information, please contact the manufacturer.

 

The manufacturer believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but without guarantee, as conditions and methods of use of products are beyond the manufacturer’s control. The manufacturer assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user’s responsibility to determine the appropriateness of the products for the user’s specific end uses.

 

hf5
Part Number Description
208125 MEMBRANE, HF5, 2514, DRY, AXEON
208083 MEMBRANE, HF5, 2521, DRY, AXEON
208084 MEMBRANE, HF5, 2540, DRY, AXEON
200392 MEMBRANE, HF5, 4014, DRY, AXEON
200393 MEMBRANE, HF5, 4021, DRY, AXEON
200394 MEMBRANE, HF5, 4040, DRY, AXEON
AXEON HF5-SERIES MEMBRANE ELEMENTS SPECIFICATION SHEET
AXEON HF5-SERIES MEMBRANE ELEMENTS SPECIFICATION SHEET
 
DOWNLOAD
AXEON MEMBRANE ELEMENTS AND MEMBRANE HOUSINGS BROCHURE
AXEON MEMBRANE ELEMENTS AND MEMBRANE HOUSINGS BROCHUR
 
DOWNLOAD
AXEON MEMBRANE ELEMENTS WARRANTY
AXEON MEMBRANE ELEMENTS WARRANTY
 
DOWNLOAD
AXEON MEMBRANE ELEMENT COMPARISON CHART
AXEON MEMBRANE ELEMENT COMPARISON CHART
 
DOWNLOAD